The 152-IRB Thermometer was designed to measure cutaneous temperature of small rodents very fast and contactless.  With the 152-IRB Thermometer, we especially focused on the optical dimension and the position of the IR sensor in order to allow measurements on very small surfaces without allowing the sensor to get wrong values with integration of environment temperature, which can be the case with other industrial type Infra red thermometers. This thermometer thus allows easy measurements even on mice tails - with high accuracy and repeatability. The cutaneous measurement should be correlated with usual rectal temperatures (see the RET-2 and 3 rectal probes for rodents).

The 152-IRB thermometer is especially accurate on a temperature range from 25 to 40 °C and will prove to be useful for other lab applications as well.

Technical Specifications (room temperature of 15 to 25°C):

bullet

Resolution: 0.1°C

bullet

Accuracy: 0.3°C from 25 to 40°C

bullet

Accuracy outside of the 25-40°C range: 1% +/- 1°C

bullet

Global measurement range: -20°C to +200°C

bullet

Distance ratio: 1:1.5

bullet

Min. distance to object from: 0 mm

bullet

Min. measurement size: 3mm

bullet

Emissivity fixed, undisclosed value

Infrared temperature, guidelines and important notice:  Infrared temperature measurement consists in the detection of the quantity of light emitted by the measured object - the optical signal received by the sensor being then converted into an electrical signal. The instruments are equipped with a lens to concentrate the light on the sensor. This lenses have different characteristics according to the object you want to measure (diameter, focal length, viewing angle or distance ration between the surface "seen" by the lens and the distance to the object).

Another parameter should be taken into account: the emissivity (or amount of emitted light) of the measured object. The focal specifications of typical general thermometers usually allow the measurement of objects from a minimum distance of 10 to 25 mm with a minimum target size of 15mm and a distance ratio of 1:10, the emissivity is generally fixed to 0,95. Such thermometers are therefore not able to measure from less than 10 mm from the object, and this measurement includes all points in a circle of 15 mm of diameter. If the object is situated 50cm away, the surface of measurement will have a diameter of 5 cm. Theses dimensions are fully inadequate for cutaneous temperature measurements in rodents... which is precisely the reason why we developed the 152-IRB Thermometer.

Measurement taken in the animal fur may include the ambient air caught in the hair, thus creating important measurement variations. It's therefore advisable to measure on naked surfaces, like skin, tail, nose, genital area...

Model Dimension

Price

IR-B152 Small Rodent Infrared Thermometer $675.00/Each Click Here To Add To Your Shopping Cart!

Go to Cart

How to Choose the Right Model
 
ST ProPlus Series Infrared Thermometer

Ensure precise temperature measurements with the enhanced eight-point Laser Guide™ sighting system and adjustable emissivity permitting quicker, easier targeting, and more accurate temperature measurements. Advanced optics allow the temperature of smaller objects to be taken from greater distances.   Selectable MAX, MIN, DIF and AVG functions perform calculations instantly.

Features
bullet 1% (±1°C) accuracy
bullet Single point class 2 laser sighting
bullet Backlit LCD display with MAX, MIN, DIF, AVG, SCAN, HOLD functions
bullet Settable Hi-Lo alarm
bullet Adjustable emissivity
bullet Data-logging (12 pts)
bullet RTD probe jack
bullet °F/°C switchable
bullet Black with yellow overmolded highlights.

Clearance  Items | Products | Home

ST60 ProPlus
 
bullet Optical Resolution (D:S) 30:1
bullet Typical Distance to Target Spot up to 4.5m or 15 ft
bullet Temperature Range -25° to 1100°F (-32°-600°C)

Comes complete with lanyard, 7-language display box and user manual (English, French, German, Spanish, Portuguese, Chinese, Japanese), multi-lingual/multi-region laser warning label sheet, 9V battery, protective hard case, warranty card.

Model Description

Price

IR-ST60 ST ProPlus Thermometer $600.00/Each Click Here To Add To Your Shopping Cart!
ST80 ProPlus
 
bullet Optical Resolution (D:S) 50:1
bullet Typical Distance to Target Spot up to 7.5m or 25 ft
bullet Temperature Range -25° to 1400°F (-32°-760°C)

Comes complete with lanyard, 7-language display box and user manual (English, French, German, Spanish, Portuguese, Chinese, Japanese), multi-lingual/multi-region laser warning label sheet, 9V battery, protective hard case, warranty card.
 

Model Description

Price

IR-ST80 ST ProPlus Thermometer $625.00/Each Click Here To Add To Your Shopping Cart!

Go to Cart


Clearance  Items | Products | Home
 
MX Series Infrared Thermometer
Noncontact Temperature Measurement


Features
bullet Temperature Range: -30° to 900°C (-25° to 1600°F)
bullet Accuracy: (Assumes ambient operating temperature of 23ºC (73ºF)) ±0.75% of reading or ±1ºC (±2ºF) whichever is greater
bullet Response Time: 250 m Sec (95% of reading)
bullet Spectral Response: 8 to 14µm, thermopile detector
bullet  Distance to Spot (D:S): 60:1 (50:1 with Close Focus Option)
bullet Minimum Measurement Diameter: 19mm (.76") (6mm (0.24") with Close Focus Option)
bullet Display Resolution: 0.1ºC of reading up to 900ºC (0.2ºF up to 999.8ºF)
bullet Temperature Display: ºC or ºF selectable
bullet Ambient Operating Temperature: 0 to 50ºC (32 to 120ºF )
bullet Repeatability: less than ±0.5 of reading or less than ±1ºC (±2ºF), whichever is greater
bullet Storage Temperature: -20 to 50ºC (-25º to 122ºF)
bullet Tripod Mount: 1/4-20 UNC
 
Broad temperature range, superior optics and the True Spot™ double-bright circular laser sighting system make the MX series the most advanced portable thermometer in the industry.  The MX series featuring the True Spot™ coaxial laser sighting is the only thermometer designed with precise infrared beam tracking, resulting in more accurate measurement.

True Spot™ is a coaxial circular laser sighting system that profiles the infrared beam at all distances, allowing the laser circle to consistently show the measurement area.  This advanced coaxial system uses an extra bright 635nm, 16 point laser circle to clearly highlight the targeted area.

The Close Focus (CF) option is available at no extra charge and lets you accurately measure very small areas at the Focus Point where the IR beam narrows. Paired with the advanced coaxial laser sighting, extremely small objects 6 mm (.24 in) can be easily measured.

MX2 Infrared Thermometer
 

MX Brochure

Model Dimension

Price

IR-MX2-CF MX2 Infrared Thermometer (close focus) $925.00/Each Click Here To Add To Your Shopping Cart!

Go to Cart


MX4+ Infrared Thermometer

The MX4+ stores up to 100 temperature readings for easy retrieval and when used with the DataTemp MX software, can store customized location names and alarms for data logging and mistake free inspections and reliable data recording. 

Visualize, systematically maintain and analyze temperature data using Windows compatible DataTemp MX software.  Easily see temperature trends and potential problems by graphing data accumulated with the MX's data logging feature.  The MX4+ can be used to monitor, graph and record real-time temperature changes with the DataTemp software.  The DataTemp software provides a convenient way to export temperature data files in a format that can be used by programs such as Access®, Exel®, and condition monitoring programs. 

MX Brochure

Model Dimension

Price

IR-MX4-CF MX4+ Infrared Thermometer w/software
(close focus)
$1,510.00/Each Click Here To Add To Your Shopping Cart!

 

 

©2001 Braintree Scientific, Inc. Address: PO Box 361 Braintree, MA 02185
Phone: 781-348-0768 
FAX: 781-843-7932

e-mail: Info@braintreesci.com

Prices Subject to Change without Notice
Prices are Valid for U.S. Customers Only

All rights reserved. No portion of this Web site should be copied.
This web-site was last updated 10/21/2008